Honeywell UDA2182‑PH1‑NN2‑NN‑N‑00C0‑EE Universal Dual Analytical Analyzer
Warranty: 365 days
Quality: Original module
Condition: New / Used
Warehouse: Spot
Delivery time: Shipped in 3 days after payment
WhatsApp:+86 18030183032
Mailbox:3248602330@qq.com
Введите текст заголовка
Honeywell UDA2182‑PH1‑NN2‑NN‑N‑00C0‑EE Universal Dual Analytical Analyzer
Product Description
The UDA2182‑PH1‑NN2‑NN‑N‑00C0‑EE is Honeywell Universal Dual‑Input process liquid analytical analyzer/controller belonging to UDA2182 platformHoneywell. Order code breakdown: ‑ PH1: Channel‑1 = pH/ORP measurement input card ‑ NN2: Channel‑2 = No input module fitted ‑ NN: No extra analog output / relay expansion ‑ N: No communication option fitted ‑ 00: Panel‑mount only, no pipe‑wall mounting kit ‑ C0: Calibration conformance certificate included ‑ EE: Multi‑language firmware (English / French / German / Spanish / Italian)Honeywell
This unit supports pH and ORP continuous monitoring & closed‑loop PID control for liquid process streams. It adopts plug‑in interchangeable input‑card architecture, graphic back‑lit display, menu‑driven local configuration. Original factory production is discontinued; only NOS surplus, refurbished units and factory repair service are available for legacy plant retrofits and spare‑part replacement. Country of Origin: Mexico。

UDA2182-PH1-NN2-NN-N-00C0-EE
Technical Specifications
| Item | Specification |
|---|---|
| Part Number | UDA2182‑PH1‑NN2‑NN‑N‑00C0‑EE |
| Product Type | Universal Dual‑Input Liquid Analytical Analyzer & Controller |
| Installed Input Channel | Ch1: pH / ORP; Ch2: Not equipped (NN2) |
| Measurement Range‑pH | 0‑14 pH |
| Measurement Range‑ORP | ‑1500 ~ +1500 mV |
| Temperature Compensation | Automatic Pt100 / Pt1000 RTD compensation |
| Analog Output | 2 × 4‑20 mA (base unit); no extra expansion outputs |
| Relay Output | 2 alarm relays (base unit), 4 A @120/240VAC, 4 A @30VDC resistive load |
| Control Function | Built‑in PID control for pH neutralization process |
| Display | Back‑lit graphic LCD multi‑line display |
| Power Supply | 90‑264 VAC, 47‑63 Hz, 15 VA max consumption |
| Form Factor | 1/4‑DIN panel‑mount housing (138 mm ×138 mm) |
| Weight | 1.85 kg (4.08 lb) |
| Operating Temperature | 0 °C ~ +60 °C |
| Storage Temperature | ‑20 °C ~ +70 °C |
| Relative Humidity | 5‑95 % RH, non‑condensing |
| Enclosure Rating | NEMA 4X / CSA Type4X front panel |
| Hazardous Approval | FM Class I Div.2 Groups A,B,C,D T4 |
| Certification | CE, UL, CSA |
| Communication | No onboard communication card (N option); IR infrared local service port |
| Product Status | Discontinued OEM production, aftermarket spare‑part only |
Key Features & Benefits
- Modular plug‑and‑play input‑card design: Field‑replaceable analytical input cards; this variant is configured for pH‑ORP single‑channel operation, can later retrofit conductivity or dissolved‑oxygen cards on‑site without sending unit back to factory.
- Integrated PID closed‑loop control: Built‑in PID algorithm directly drives dosing valves / chemical metering pumps for pH neutralization treatment, reduces requirement for external PLC control loops.
- Rich local human‑machine interface: Backlit graphic LCD, multi‑language menu, local calibration wizard, on‑board event log stores calibration records, alarm history and diagnostic faults.
- Flexible alarm relay logic: Two configurable alarm relays support high‑pH / low‑pH, sensor fault, temperature alarm; relay dry‑contacts connect to local annunciator or DCS interlock.
- Harsh‑environment robust construction: NEMA4X front panel, Class I Div2 hazardous‑area certification, suitable for chemical plant, water‑treatment cabinet field installation.
- Traceable calibration documentation: Factory calibration conformance certificate included (‑C0 option), satisfies pharmaceutical, power‑plant QA audit requirements.
- Local IR service interface: Wireless infrared port supports handheld tool for parameter upload/download without opening cabinet wiring terminals.
Application Fields
‑ Power‑generation plants: Boiler feed‑water, condensate water, pure‑water system pH & ORP monitoring and chemical dosing control. ‑ Waste‑water treatment plant: pH neutralization process control for influent‑effluent discharge. ‑ Chemical & petrochemical industry: Liquid‑phase pH/ORP continuous analysis for reaction vessels. ‑ Pharmaceutical & food‑beverage: Process water quality monitoring with calibration‑audit requirement. ‑ Pulp‑and‑paper mill: Bleaching‑process ORP monitoring. ‑ Spare‑part replacement for existing UDA2182 installed base with single‑channel pH‑ORP measurement demand.
UDA2182 Series Typical Family Models (12 variants)
- UDA2182‑PH1‑PH2‑C3‑E‑0000‑EE: Dual pH/ORP inputs, expanded outputs, Ethernet Modbus communication
- UDA2182‑CC1‑CC2‑NN‑N‑0000‑EE: Dual contacting conductivity input analyzer
- UDA2182‑DM1‑NN2‑C3‑E‑0000‑EE: Dissolved‑Oxygen ppm single‑channel with expanded relays and Ethernet
- UDA2182‑DB1‑NN2‑NN‑N‑0000‑EE: Dissolved‑Oxygen ppb high‑purity‑water measurement
- UDA2182‑PH1‑CC2‑NN‑N‑0000‑EE: Ch1 pH‑ORP, Ch2 conductivity mixed‑measurement
- UDA2182‑PH1‑DM2‑C3‑E‑0P00‑EE: pH + dissolved‑oxygen ppm, pipe‑wall mounting hardware
- UDA2182‑PA1‑NN2‑NN‑N‑00C0‑EE: Pre‑amplified pH input with calibration certificate
- UDA2182‑CC1‑DM2‑C3‑E‑0000‑EE: Conductivity + dissolved‑oxygen ppm dual‑channel
- UDA2182‑PH1‑NN2‑C3‑E‑0000‑RT: pH single‑channel, Russian‑Turkish language firmware
- UDA2182‑CC1‑NN2‑NN‑N‑00C0‑EE: Single‑channel conductivity analyzer with calibration cert
- UDA2182‑DM1‑DB2‑C3‑E‑0000‑EE: Dual‑DO ppm + ppb mixed‑input configuration
- UDA2182‑PH1‑DB2‑NN‑N‑0000‑EE: pH‑ORP + ppb dissolved‑oxygen dual‑channel for high‑purity water
Installation Guidance
- Mechanical panel‑mount installation: Cut standard 1/4‑DIN panel cut‑out 138×138 mm; insert UDA2182 unit from front of panel; fasten rear mounting clamps securely; keep sufficient rear‑side ventilation clearance for heat dissipation. This part number 00 suffix: no pipe‑wall mounting accessories supplied.
- Sensor field wiring: Connect pH/ORP glass electrode and RTD temperature compensation sensor to rear Ch‑1 input terminals; strictly follow Honeywell sensor wiring diagram; use shielded low‑noise cable for pH probe signal wiring, separate from high‑power AC power cables to avoid interference.
- Power wiring: Connect 90‑264 VAC power supply to rear power terminals; install external fuse per electrical safety requirement.
- Output‑relay & analog‑output wiring: Wire 4‑20 mA analog outputs to DCS / recorder; wire alarm‑relay dry‑contacts to external alarm interlock circuit, respect relay contact load rating.
- Commissioning & configuration: Power‑on unit; navigate front‑panel menu, define sensor type, set PID control parameters, configure alarm threshold; perform two‑point buffer‑solution pH calibration. Review event‑log after calibration completion.
Important Notes ‑ Channel‑2 slot on this unit is empty (NN2); if second‑parameter measurement is required, purchase and install corresponding plug‑in input card locally. ‑ This specific part number has NO Ethernet / Modbus communication card fitted; only IR local service interface available. ‑ Sensor cable shall not be bundled together with motor power cables to prevent high‑frequency noise drifting pH readings.
Maintenance Recommendations
- Routine inspection: Check front‑panel display status, inspect rear terminals for loose wiring and dust accumulation.
- Periodic calibration: Perform pH two‑point buffer calibration on site following plant maintenance schedule. Download event log via IR handheld tool to review calibration history and sensor‑fault records.
- Replace pH glass electrode according to process medium fouling condition.
- For input‑card upgrade: Power‑off analyzer before swapping plug‑in input modules.
- Refer to Honeywell official manual document 51‑52‑16U‑85 for complete installation constraints, calibration procedure and troubleshooting guidance.