| H201Ti (Base Unit) | The standard composite gas sensor model. Variant codes (e.g., H201Ti-CE-X2-V1-VC0-H1-L1-F1) denote specific options like enclosure type, communication protocols, display, alarm relays, etc. starfishpps.com+1 |
| H201Ti-H2 (Hydrogen Only) | A variant equipped with a sensor sensitive only to Hydrogen (100% response), often used for applications where hydrogen is the sole fault gas of interest. plccontrol.cn |
| H201Ci-1 Controller | Single-channel controller that processes data from one H201Ti transmitter, providing local display, alarming, and communication capabilities. plccontrol.cn |
| H201Ci-4 Controller | Four-channel controller that can aggregate data from up to four H201Ti transmitters. plccontrol.cn |
| H201Ci-C Controller | A communication-focused controller (no display) for integrating multiple H201Ti units into a larger network. plccontrol.cn |
Введите текст заголовка
GE H201Ti Hydran™ 201Ti – Intelligent Dissolved Gas Transmitter
1. Product Brand, Model & Title
| Field | Information |
|---|---|
| Brand | GE (General Electric) / GE Vernova xydcontrol.com+1 |
| Model | H201Ti (also written as HYDRAN 201Ti) plccontrol.cn+1 |
| Product Title | Intelligent Dissolved Gas Transmitter (DGA Monitor) |
| Series | HYDRAN™ 200 Series plccontrol.cn |
| System Platform | GE HYDRAN 201i Transformer Monitoring System xydcontrol.com |
2. Executive Brief
The GE H201Ti is a compact, continuous online dissolved gas analysis (DGA) transmitter designed for permanent installation on power transformers cxabb.com+1. It serves as the core sensing unit within the HYDRAN™ 201i system, providing real-time, early warning of developing electrical and thermal faults inside transformers by continuously monitoring key fault gases (Hydrogen, Carbon Monoxide, Acetylene, Ethylene) dissolved in the insulating oil plccontrol.cn+1. Utilizing advanced fuel cell sensor technology, it delivers a single composite gas value (primarily H2 equivalent) without the need for pumps or moving parts, ensuring high reliability and minimal maintenance plccontrol.cn+2. This globally-deployed device (over 25,000 units installed) is compliant with IEEE C57.104 standards and helps operators maximize asset availability while minimizing unplanned outages plccontrol.cn.

H201Ti
3. Core Technical Specifications
| Parameter Category | Specification | Details |
|---|---|---|
| Measurement | Sensor Type | Fuel Cell Composite Gas Sensor plccontrol.cn+2 |
| Primary Target Gas | Hydrogen (H₂) — 100% response plccontrol.cn+1 | |
| Additional Gases Sensitive | Carbon Monoxide (CO: 18±3%), Acetylene (C₂H₂: 8±2%), Ethylene (C₂H₄: 1.5±0.5%) plccontrol.cn+1 | |
| Measurement Range | 0 – 2000 ppm (Hydrogen equivalent volume/volume) plccontrol.cn | |
| Accuracy | ±10% of reading or ±25 ppm (whichever is greater) at 35°C setpoint plccontrol.cn | |
| Communication | Interfaces | RS-485 (Modbus® RTU / Hydran Protocol) plccontrol.cn+2 USB Type B (Local Configuration) xydcontrol.com+1 |
| Data Logging | Up to 1 year of local historical data storage plccontrol.cn+1 | |
| Power Supply | Voltage | 90 – 264 VAC, 50/60 Hz (Auto-switching) manualslib.com+1 |
| Power Consumption | 475 VA maximum manualslib.com | |
| Environmental | Operating Temperature | -40°C to +55°C (Monitor), up to +105°C (Valve with adapter) plccontrol.cn+1 |
| Storage Temperature | -40°C to +70°C plccontrol.cn | |
| Humidity | 0 – 95% RH (non-condensing) plccontrol.cn | |
| Protection Rating | NEMA Type 4X / IP56 plccontrol.cn+1 | |
| Physical | Installation Type | Direct mount on single transformer oil sampling valve (via brass adapter) plccontrol.cn+2 |
| Weight | 5.6 kg plccontrol.cn | |
| Dimensions | Compact, NEMA 4X cylindrical enclosure cxabb.com+1 | |
| Diagnostics | Self-Test | Automatic full system self-test every 15 days plccontrol.cn |
| Alarm Outputs | 3 SPDT Relays (Gas High, Gas High-High, System Fault) plccontrol.cn+1 | |
| Display | Backlit LCD (2 lines x 16 characters) plccontrol.cn+1 |
4. Key Features and Advantages
- Advanced Fuel Cell Sensor Technology: Provides a direct, stable, and highly sensitive measurement of fault gases, particularly Hydrogen, without the need for carrier gas or complex gas separation plccontrol.cn+1. This technology offers excellent selectivity and long-term stability.
- Simple, Maintenance-Free Design: The no-moving-parts, no-pump design eliminates common failure points associated with traditional DGA monitors. It mounts directly onto a standard transformer drain or sampling valve, requiring no additional plumbing or oil circulation plccontrol.cn+1. This reduces installation complexity and ongoing maintenance to virtually zero.
- Robust, Self-Contained Architecture: The H201Ti integrates the sensor, microprocessor, thermal regulation, and communication interfaces into a single, rugged IP56-rated enclosure cxabb.com+1. This compact, self-contained unit is designed to withstand harsh substation environments, including extreme temperatures, vibration, and electrical noise.
- Intelligent Diagnostic & Self-Test Capabilities: The microprocessor continuously monitors the sensor’s health and system status. It performs an automatic full system self-test every 15 days, checking for power loss, oil valve closure, sensor malfunction, and battery failure. Any detected issue triggers a service alarm plccontrol.cn.
- Integrated Data Logging & Flexible Alarming: The transmitter stores up to one year of historical data locally, allowing for trend analysis and fault diagnosis even without communication. Three programmable alarm relays provide local indication and remote annunciation of gas levels and system status plccontrol.cn+1.
- Seamless System Integration: Designed as part of the larger HYDRAN 201i system, the H201Ti communicates with H201Ci series controllers (H201Ci-1, H201Ci-4, H201Ci-C) and GE Perception™ Fleet software for advanced data management, analysis, and reporting plccontrol.cn+1. It supports both Modbus RTU and proprietary Hydran protocols.
5. Application Scenarios
The H201Ti is critical for the asset management of large, expensive, and strategically important power transformers where unplanned outages can have significant economic and operational impacts.
- Power Generation Plants: Monitoring main generators and unit auxiliary transformers in thermal, hydro, and nuclear power plants to prevent catastrophic failures.
- Electric Utilities & Substations: Deployed on transmission and distribution class transformers to enhance grid reliability and enable condition-based maintenance (CBM) strategies.
- Industrial Power Systems: Protecting large in-plant transformers in petrochemical, mining, steel, and manufacturing facilities where process continuity is paramount.
- Renewable Energy Integration: Monitoring step-up transformers in wind and solar farms to ensure reliable energy transmission to the grid.
- Retrofit & Modernization Projects: Its straightforward, single-valve installation makes it ideal for upgrading the monitoring capabilities of existing transformers without major modifications.

H201Ti
6. Brand Related Models
| Model Number | Relation to H201Ti |
|---|---|
| H201Ti (Base Unit) | The standard composite gas sensor model. Variant codes (e.g., H201Ti-CE-X2-V1-VC0-H1-L1-F1) denote specific options like enclosure type, communication protocols, display, alarm relays, etc. starfishpps.com+1 |
| H201Ti-H2 (Hydrogen Only) | A variant equipped with a sensor sensitive only to Hydrogen (100% response), often used for applications where hydrogen is the sole fault gas of interest. plccontrol.cn |
| H201Ci-1 Controller | Single-channel controller that processes data from one H201Ti transmitter, providing local display, alarming, and communication capabilities. plccontrol.cn |
| H201Ci-4 Controller | Four-channel controller that can aggregate data from up to four H201Ti transmitters. plccontrol.cn |
| H201Ci-C Controller | A communication-focused controller (no display) for integrating multiple H201Ti units into a larger network. plccontrol.cn |
| Perception™ Software | GE’s advanced fleet management software for collecting, storing, analyzing, and reporting DGA data from multiple H201Ti units across an enterprise. plccontrol.cn+1 |
7. Frequently Asked Questions (FAQ)
Q1: What is the difference between the composite gas sensor and the hydrogen-only sensor?
A: The composite gas sensor (standard) is primarily sensitive to Hydrogen (100%) but also provides calibrated sensitivity to Carbon Monoxide (CO), Acetylene (C₂H₂), and Ethylene (C₂H₄) plccontrol.cn+1. This gives a broader indication of fault types (e.g., CO for paper overheating). The hydrogen-only sensor is highly sensitive to Hydrogen alone. Hydrogen is the most common fault gas and the first to appear in many fault scenarios. The hydrogen-only sensor is chosen for applications where hydrogen is the sole parameter of interest, potentially offering faster response for H₂-only detection.
Q2: How is the H201Ti powered and what are its communication capabilities?
A: The H201Ti is powered by standard AC mains (90-264 VAC, 50/60 Hz), typically wired to an external circuit-breaker manualslib.com+1. For communication, it features an isolated RS-485 port that supports both the Modbus® RTU protocol (for integration into SCADA systems) and the proprietary Hydran protocol (for communication with H201Ci controllers) plccontrol.cn+2. It also has a USB Type B port for local configuration and data download using a PC xydcontrol.com+1.
Q3: Does the H201Ti require periodic calibration or replacement of consumable parts?
A: The H201Ti is designed to be virtually maintenance-free. Its fuel cell sensor does not require periodic calibration. The only consumable component is the lithium battery (typically 3V, 950mAh) which provides memory backup for configuration and historical data during power loss rsmodules.com. The battery life is typically several years, and the transmitter will alert you when it needs replacement.
Q4: How do I install the H201Ti on my transformer?
A: The H201Ti is designed for direct mounting onto a standard transformer oil sampling or drain valve using a supplied brass adapter plccontrol.cn+2. This eliminates the need for any additional piping or pumps. The oil flows naturally into the transmitter’s sensor manifold by gravity and the slight pressure difference, allowing continuous, dynamic sampling. Ensure the valve is clean, the O-ring is correctly positioned, and the adapter is securely tightened. Always follow the detailed installation procedure in the manual manualslib.com.
Q5: What happens if the H201Ti detects a gas alarm or a system fault?
A: Upon detecting a gas level exceeding the programmed setpoints (High or High-High) or an internal system fault (e.g., sensor failure, power loss), the H201Ti will:
- Energize one of its built-in alarm relays (SPDT, 3A@250VAC) to trigger local annunciators, lights, or horns plccontrol.cn+1.
- Generate a corresponding message that can be communicated via Modbus to a remote SCADA system or H201Ci controller.
- Log the event as a “major event” in its internal non-volatile memory for later review rsmodules.com.
The local LCD will also display the specific alarm condition. The response to the alarm (e.g., initiating a shutdown, scheduling maintenance) is determined by the user’s defined operating procedures and the control system logic.