You are here:

Bently Nevada 3500/15 129478-01 Legacy High Voltage DC Power Input Module

Warranty: 365 days
Quality: Original module
Condition: New / Used
Warehouse: Spot
Delivery time: Shipped in 3 days after payment
WhatsApp:+86 18030183032
Mailbox:3248602330@qq.com

Классификация:

Введите текст заголовка

Bently Nevada 3500/15 129478-01 Legacy High Voltage DC Power Input Module

Overview

The Bently Nevada 3500/15 129478-01 is a Legacy High Voltage DC Power Input Module (PIM) designed for the 3500 Series Machinery Protection System. As a half-height rear-mounted module, it interfaces with the 3500/15 High Voltage DC Power Supply (129486-01) to convert an 88–140 Vdc input into regulated DC power for all rack-mounted monitoring, protection, and communication modules. This PIM is deployed in critical rotating machinery applications—including gas turbines, steam turbines, compressors, and large motors—where high-voltage DC plant power or battery systems are the preferred source.

350015 129478-01

350015 129478-01

350015 129478-01

350015 129478-01


Specifications & Parameters

Parameter Specification
Part Number 129478-01
Product Family 3500/15 Power Supply
Module Type Legacy High Voltage DC Power Input Module (PIM)
Input Voltage 88 to 140 Vdc

Full Rack Current Draw 2.5 A (maximum)

Output Voltage Regulated DC (for 3500 rack modules)
Isolation Voltage 1500 VAC, 60 Hz for 1 minute
Overvoltage Category II
Operating Temperature –30 °C to +65 °C (–22 °F to +150 °F)

Storage Temperature –40 °C to +85 °C (–40 °F to +185 °F)
Humidity 0% to 95% RH, non-condensing

Module Dimensions (H × W × D) 120.7 mm × 25.4 mm × 114.3 mm (4.75 in × 1.0 in × 4.5 in)

Module Weight Approx. 0.34 kg (0.75 lb)
Form Factor Half-height rack module
Mounting Position Left-side dedicated slot, directly behind the associated power supply module
Country of Origin USA
Replacement Fuse 01720025 (shared with AC PIMs and High Voltage DC PIMs)


Key Features & Characteristics

  • High-Voltage DC Input Range: Accepts 88–140 Vdc, making it suitable for industrial 125 Vdc battery banks and high-voltage DC distribution systems commonly found in power generation and substation environments.

  • Redundant Power Architecture: The 3500 rack supports dual power supply configurations. When two supplies are installed, the module in the lower slot functions as the primary source, while the module in the upper slot serves as the backup. Upon primary failure, the backup assumes the full rack load seamlessly without system interruption.

  • Hot-Swap Capability: Under redundant configurations, either the power supply or the PIM can be removed or inserted without disrupting rack operation, provided the second supply remains active. This enables online maintenance and minimizes downtime in continuous-process industries.

  • Front-Panel Status Indication: The associated power supply module (129486-01) features a Supply OK LED that provides immediate visual confirmation of proper DC output regulation and overall power supply health.

  • Compact Half-Height Design: The PIM’s slim 25.4 mm (1.0 in) width maximizes available rack real estate, leaving the full complement of slots available for monitoring, communication, and relay modules.
  • Overvoltage & Undervoltage Protection: An under-voltage condition will not damage the supply or the PIM. An over-voltage event causes the PIM fuse to open, protecting downstream 3500 modules from electrical stress.

  • No Minimum Load Requirement: The 3500/15 power system operates correctly even with a lightly populated rack, eliminating concerns about minimum module counts.


Installation Guidelines

  1. Rack Positioning: The 3500/15 Power Supply and its associated PIM must be installed in the designated half-height slots on the left side of the 3500 rack. The PIM mounts directly behind its corresponding power supply module (129486-01).

  2. Dual-Supply Configuration: For redundancy, install one supply in the lower slot (primary) and the second in the upper slot (backup). Any combination of AC and DC supplies is permitted—allowing, for example, a primary 125 Vdc supply with a backup 120 Vac supply for maximum power source diversity.

  3. Single-Supply Configuration: If only one power supply is required, leave the second slot empty or install a blank front panel (P/N 131150-01).
  4. Wiring: Use the replacement connector P/N 118M0915-02 for DC Power Input Module wiring. Ensure correct polarity, adequate wire gauge for up to 2.5 A, and proper grounding per local electrical codes.

  5. Environmental Compliance: Install within the specified temperature and humidity ranges. Avoid condensing environments to prevent moisture ingress and terminal corrosion.

Repair & Maintenance

  • Fuse Replacement: The 129478-01 shares the replacement fuse P/N 01720025 with AC PIMs and other High Voltage DC PIMs. Always verify the redundant supply is active and the Supply OK LED is illuminated on the backup before removing the primary PIM for fuse service.

  • Module Replacement: Thanks to hot-swap support, a faulty 129478-01 can be replaced while the rack remains powered by the redundant supply. After insertion, confirm the Supply OK LED on the front power supply module illuminates steadily.
  • Troubleshooting: If the Supply OK LED is extinguished:
    • Verify input voltage at the PIM terminals is within 88–140 Vdc.
    • Inspect and replace fuse P/N 01720025 if an over-voltage event is suspected.
    • Confirm rack load does not exceed the 2.5 A maximum.
    • Check for loose or corroded DC input connections.
    • Persistent failure typically indicates internal PIM or power supply module degradation requiring full module replacement.
  • Spare Parts Strategy: Maintain on-site spares of both the PIM (129478-01) and its front power supply module (129486-01) to minimize Mean Time To Repair (MTTR) in critical machinery protection loops.

Same-Series Models & Compatible Part Numbers

The 3500/15 family encompasses multiple voltage options and generations. The following models are part of the same series ecosystem:
Part Number Description Input Voltage
129478-01 Legacy High Voltage DC PIM 88–140 Vdc
129486-01 Legacy High Voltage DC Power Supply Module (front panel) Pairs with 129478-01
125840-01 High Voltage AC PIM (legacy) 175–264 Vac RMS
125840-02 Low Voltage AC PIM (legacy) 85–132 Vac RMS
133292-01 Legacy Low Voltage DC Power Supply Module 20–30 Vdc
133300-01 Legacy Low Voltage DC PIM 20–30 Vdc
114M5329-01 New-Generation High Voltage DC Power Supply Module 88–140 Vdc
115M7750-01 New-Generation High Voltage DC PIM 88–140 Vdc
114M5330-01 New-Generation Low Voltage DC Power Supply Module 20–30 Vdc
114M5335-01 New-Generation Low Voltage DC PIM 20–30 Vdc
106M1079-01 Universal AC Power Supply Module (new generation) 85–264 Vac RMS
106M1081-01 Universal AC PIM (new generation) 85–264 Vac RMS
01720025 Replacement Fuse (AC and High Voltage DC PIMs) —
01720045 Replacement Fuse (Low Voltage DC PIM) —
118M0915-02 Replacement Connector (DC PIM) —

Ordering Code Structure (3500/15-AXX-BXX-CXX)

Position Code Meaning
A (Top Slot) 01 Low Voltage AC (85–132 Vac)
02 High Voltage AC (175–264 Vac)
03 High Voltage DC (88–140 Vdc) — Legacy
04 Low Voltage DC (20–30 Vdc) — Legacy
05 Universal AC (85–264 Vac) — New Generation
06 High Voltage DC (88–140 Vdc) — New Generation
07 Low Voltage DC (20–30 Vdc) — New Generation
00 No Power Supply
B (Bottom Slot) Same as A Backup supply type (or 00 for single supply)
C (Approval) 00 No Agency Approval
01 CSA/NRTL/C (Class 1, Division 2)
02 ATEX/IECEx/CSA (Class 1, Zone 2)
Example Configurations:
  • 3500/15-03-03-00: Dual Legacy High Voltage DC supplies (redundant)
  • 3500/15-03-00-00: Single Legacy High Voltage DC supply
  • 3500/15-03-05-00: Legacy High Voltage DC primary + Universal AC backup (mixed redundancy)